IEC 61970-457:2024 specifies a standard interface for exchanging dynamic model information needed to support the analysis of the steady state stability (small-signal stability) and/or transient stability of a power system or parts of it. The schema(s) for expressing the dynamic model information are derived directly from the CIM, more specifically from IEC 61970-302.
The scope of this document includes only the dynamic model information that needs to be exchanged as part of a dynamic study, namely the type, description and parameters of each control equipment associated with a piece of power system equipment included in the steady state solution of a complete power system network model. Therefore, this profile is dependent upon other standard profiles for the equipment as specified in IEC 61970-452: CIM static transmission network model profiles, the topology, the steady state hypothesis and the steady state solution (as specified in IEC 61970-456: Solved power system state profiles) of the power system, which bounds the scope of the exchange. The profile information described by this document needs to be exchanged in conjunction with IEC 61970-452 and IEC 61970-456 profiles’ information to support the data requirements of transient analysis tools. IEC 61970-456 provides a detailed description of how different profile standards can be combined to form various types of power system network model exchanges.
This document supports the exchange of the following types of dynamic models:
• standard models: a simplified approach to exchange, where models are contained in predefined libraries of classes interconnected in a standard manner that represent dynamic behaviour of elements of the power system. The exchange only indicates the name of the model along with the attributes needed to describe its behaviour.
• proprietary user-defined models: an exchange that would provide users the ability to exchange the parameters of a model representing a vendor or user proprietary device where an explicit description of the model is not described in this document. The connections between the proprietary models and standard models are the same as described for the standard models exchange. Recipient of the data exchange will need to contact the sender for the behavioural details of the model.
This document builds on IEC 61970-302, CIM for dynamics which defines the descriptions of the standard dynamic models, their function block diagrams, and how they are interconnected and associated with the static network model. This type of model information is assumed to be pre-stored by all software applications hence it is not necessary to be exchanged in real-time or as part of a dynamics model exchange.
This second edition cancels and replaces the first edition published in 2021. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The majority of issues detected in IEC 61970-302:2018 and fixed in IEC 61970-302:2022 led to update of this document;
b) IEEE 421.5-2016 on Excitation systems is fully covered;
c) IEEE turbine report from 2013 was considered and as a result a number of gas, steam and hydro turbines/governors are added;
d) IEC 61400-27-1:2020 on wind turbines is fully incorporated;
e) WECC Inverter-Based Resource (IBR) models, Hybrid STATCOM models and storage models are added;
f) The user defined models approach was enhanced in IEC 61970-302:2022 adding a model which enables modelling of a detailed dynamic model. This results in the creation of two additional pr

  • Standard
    780 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 5832-1:2016 specifies the characteristics of, and corresponding test methods for, wrought stainless steel for use in the manufacture of surgical implants.
NOTE 1 The mechanical properties of a sample obtained from a finished product made of this alloy can differ from those specified in this part of ISO 5832.
NOTE 2 The alloy described in this part of ISO 5832 corresponds to UNS S31673 referred to in ASTM F138/ASTM F139 and to alloy code 1.4441 given in the withdrawn DIN 17443.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 2603:2016 provides requirements and recommendations for building and renovating permanent booths for simultaneous interpreting in new and existing buildings. This document also ensures the usability and accessibility of booths for all interpreters, including those with special needs.
It is applicable to all types of permanent booths, using built-in or portable equipment.
In conjunction with either this document or ISO 4043, ISO 20108 and ISO 20109 provide the relevant requirements both for the quality and transmission of sound and image provided to interpreters and for the equipment needed in the booths.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 22935-2|IDF 99-2 specifies recommended methods for the sensory evaluation of specific milk and milk products. It specifies criteria for the sampling and preparation of samples and the assessment of the samples.
ISO 22935-2|IDF 99-2 is suitable for application in conjunction with the sensory methodologies outlined in ISO 22935-1|IDF 99-1 and other ISO or IDF sensory methodologies for specific situations and products.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    23 pages
    English language
    sale 15% off
  • Draft
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 22935-3¦IDF 99-3 gives guidance on a general method for evaluation of compliance with product specifications for sensory properties based on sensory scoring and the use of a common nomenclature of terms.
The method is especially applicable in process and quality control performed regularly on a larger number of samples and/or with some time pressure and/or with a limited number of expert assessors available.
The results from the method may be part of product classification systems for domestic and international trade. Classification systems are not covered by ISO 22935-3¦IDF 99-3.

  • Standard
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    7 pages
    English language
    sale 15% off
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and recommendations for the design, use and siting of mobile booths for simultaneous interpreting. The main features of mobile booths that distinguish them from permanent booths are that they can be dismantled, moved and set up in a room. This document also ensures the usability and accessibility of booths for all interpreters.
This document is to be used in conjunction with ISO 20109, which contains requirements and recommendations for the equipment necessary for simultaneous interpreting. For requirements and recommendations for mobile booths which do not have a direct view of a room, see ISO 17651-3.[1]
[1]  Under preparation. Stage at the time of publication: ISO/CD 17651-3.2:2024.

  • Standard
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for pads for disc brakes of railway rolling stock.
The document defines requirements and generic test programs for brake pads on dynamometer. This document does not cover mandatory tests to verify stopping distances in addition to laboratory, bench test and in-service tests. In order to qualify the brake pad performance in accordance with the classification the standard provides fixed parameter figures as categories defined in paragraph classification scheme.
This document is not applicable for urban rail applications.

  • Standard
    89 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements and test methods for marketed and delivered automotive liquefied petroleum gas (LPG), with LPG defined as low pressure liquefied gas composed of one or more light hydrocarbons which are assigned to UN 1011, 1075, 1965, 1969 or 1978 only and which consists mainly of propane, propene, butane, butane isomers, butenes with traces of other hydrocarbon gases.
This standard is applicable to automotive LPG for use in LPG engine vehicles designed to run on automotive LPG.
NOTE   For the purposes of this European Standard, the terms "% (m/m)" and "% (V/V)" are used to represent respectively the mass fraction, µ, and the volume fraction, φ.
WARNING - Attention is drawn to the risk of fire and explosion when handling LPG and to the hazard to health arising through inhalation of excessive amounts of LPG.
LPG is a highly volatile hydrocarbon liquid which is normally stored under pressure. If the pressure is released large volumes of gas will be produced which form flammable mixtures with air over the range of approximately 2 % (V/V) to 10 % (V/V). This European Standard involves the sampling, handling and testing of LPG. Naked flames, unprotected electrical equipment electrostatic hazards etc. are sources of ignition for LPG.
LPG in liquid form can cause cold burns to the skin. The national health and safety regulations apply.
LPG is heavier than air and accumulates in cavities. There is a danger of suffocation when inhaling high concentrations of LPG.
CAUTION - One of the tests described in this European Standard involves the operator inhaling a mixture of air and LPG vapour. Particular attention is drawn to the cautionary statement provided in A.1, where this method is referred to.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies a method for the determination, using an oscillating U-tube density meter, of the density of crude petroleum and related products within the range 600 kg/m3 to 1 100 kg/m3, which can be handled as single-phase liquids at the test temperature and pressure.
This document is applicable to liquids of any vapour pressure as long as suitable precautions are taken to ensure that they remain in single phase. Loss of light components leads to changes in density during both the sample handling and the density determination.
This method is not intended for use with in-line density meters.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The document is applicable to the brake pad holders with which the rail vehicles of main-line railways, regional and suburban railways are fitted. Brake pad holders pursuant to this document are to be made from ferrous materials e.g. cast iron, cast steel or forged steel. Brake pad holders made of non-ferrous materials are not subject of this document.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the evaluation of the fire performance of water mist systems for lightly loaded non-storage and non-manufacturing occupancies with ordinary combustibles, such as offices, schools, hospitals and hotels.
This document is applicable to ceiling mounted and sidewall automatic nozzles to be used in restricted and/or unlimited areas.
This document is applicable for horizontal, solid, flat ceilings with heights of 2 m and above, up to the maximum tested ceiling height.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Hyperloop transport services are designed to support passenger transport and cargo transport. For each of the transport service user/customer requirements and expectations are different.
This document defines the hyperloop transport services supported by a hyperloop system and provides means for characterization and description of these services. The characterization considers the technical as well as operational / commercial features of each transport service.

  • Standard
    33 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the performance requirements for the installation of lagooning processes. This part applies to wastewater lagooning processes treating municipal wastewater from combined or separate sewerage systems and when used as a tertiary treatment.
Note: Lagooning processes are especially suitable for treatment of wastewater where large variations in flow are experienced (e.g. resulting from stormwater). Lagoon Systems are also especially suitable when there are large variation in load from seasonal industrial or tourism for example.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements for flow control devices that can be connected by the user either directly, by means of a probe or a gas-specific connector, or indirectly by means of a low-pressure hose assembly conforming with ISO 5359 to:
a)    a terminal unit conforming with ISO 9170-1 of a medical gas pipeline system conforming with ISO 7396-1:2016;
b)    the pressure outlet of a regulator conforming with ISO 10524-1:2018; or
c)    to the pressure outlet of a valve integrated pressure regulator (VIPR) conforming with ISO 10524-3 (see 5.2 gas inlets).
This document applies to the following types of flow control devices (FCDs):
a)    flowmeters;
b)    flowgauge FCDs; and
c)    fixed orifice FCDs.
NOTE       Flow control devices that are classed as medical electrical equipment can be subject to additional requirements of IEC 60601-1.
This document applies to flow control devices for the following gases:
—    oxygen;
—    oxygen 93 %;
—    nitrous oxide;
—    medical air;
—    carbon dioxide;
—    oxygen/nitrous oxide mixture 50/50 (% volume fraction);
—    oxygen-enriched air;
—    helium;
—    xenon; and
—    specified mixtures of the gases listed above.
NOTE Flow control devices can be available for other gases.
This document does not apply to flow control devices that are:
a)    for use with gases for driving surgical tools;
b)    an integral part of a regulator (see ISO 10524-1:2018); or
c)           an integral part of a valve with integrated pressure regulator (VIPR) (see ISO 10524-3).

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60068-2-86:2024 provides a test procedure for use with multi-exciter and multi-axis vibration test systems. The vibration test is intended for general application to components, equipment, and other products, hereinafter referred to as "specimens", subjected to dynamic environments that could arise during an equipment life cycle. Although this document is mainly intended for vibration testing, the procedure is also applied to certain types of shock and transient tests.

  • Standard
    42 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    32 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the laboratory test procedure for determining the clamping force exerted by the fastening system on the foot of the rail by measuring the force to separate the rail foot from its immediate support. When required, the procedure is also used to determine the uplift stiffness of the fastening system.
It is applicable to systems with and without baseplates on all types of sleepers, bearers or elements of ballastless track. The test does not determine the security of the fastening components fixed into the sleeper or other fastening system support.
This test procedure applies to a complete fastening assembly. It is not applicable to fastening systems for embedded rail or other fastening systems which do not act on the foot of the rail.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides a system for designating tooth development stages in humans using two ASCII characters.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60939-3:2024 is available as IEC 60939-3:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 60939-3:2024 covers passive filters used to attenuate unwanted radio-frequency signals (such as noise or interference) generated from electromagnetic sources. Both single and multi-channel filters within one enclosure or which are built on a printed circuit board forming a compact entity are included within the scope of this document. This document applies to passive filter units for electromagnetic interference suppression for which safety tests are appropriate. This implies that filters specified according to this document will either be connected to mains supplies, when compliance with the mandatory tests of Table B.1 is necessary, or used in other circuit positions where the equipment specification specifies that some or all of these safety tests are required. This document applies to passive filter units, which will be connected to an AC mains or other supply (DC or AC) with a nominal voltage not exceeding 1 000 V AC, with a nominal frequency not exceeding 400 Hz, or 1 500 V DC. Note: For AC use, IEC 60384-14 applies to capacitors which will be connected to AC mains with a nominal frequency not exceeding 100 Hz. This document covers appliance filters (US) but does not cover facility filters, cord-connected filters or direct plug-in filters. These other filters will be covered by another sectional specification.
This edition includes the following significant technical changes with respect to the previous edition:
a) separated clauses for safety and performance tests;
b) added note for use of multiple X capacitors bridging basic insulation in 3 phase filters;
c) characteristics and conditions to substitute X and Y capacitors are now described in a separate Subclause 4.1;
d) creepage and clearance tables updated and in line with the latest editions of IEC 60938-2 and IEC 60664-1;
e) allowing voltage measurement for inductance measurements (7.3);
f) added requirements for marking depending on remaining energy after disconnection;
g) added content of CTL DSH 2044:2016 for temperature test of IEC filters;
h) added note about temperature rise required specimens for safety testing;
i) changed index of capacitors in Annex A to avoid confusion between index name and capacitor class;
j) moved tests from group 1A to 2. Now, samples in group 1A need to be submitted without potting;
k) revision of all parts of the document has taken place based on the ISO/IEC Directives, Part 2:2021, and harmonization with other similar kinds of documents. Annex X contains all cross-references of changes in clause/subclause numbers.

  • Standard
    84 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    75 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This CEN-CENELEC Guide provides mechanisms and details the characteristics and development process of the CEN and/or CENELEC deliverable known as the 'CEN and/or CENELEC Workshop Agreement'.

  • Guide
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60352-9:2024 provides guidelines for welding and testing of ultrasonically welded connections and includes requirements, tests and practical guidance information.
Ultrasonic welding is a form of cold friction welding that is becoming increasingly popular in many industries. This type of welding uses ultrasonic vibration to join materials together, creating a bond that is both strong and reliable. Ultrasonic welding has been identified as a process in ISO 4063-41 by the International Organization for Standardization (ISO).
The process of ultrasonic welding relies on high frequency ultrasound waves being used to create frictional heat at the connection point. High temperature is not required for this special method of welding, making it one of the most cost-effective ways to join two materials together.
It also requires fewer steps than traditional methods, meaning it can be completed quickly and with minimal resources.
Ultrasonic welding has been around for decades but only recently has become more widely utilized due to advances in technology and its availability at lower cost. It can be used on many different materials including plastics, rubbers, metals, textiles, and composites. Due to its precision and strong bonds it creates, it has become extremely popular in manufacturing processes such as automotive industry, electronics industry, furniture production and even medical device production.
This document covers ultrasonically welded connections made with stranded or flexible wires (class 2, 5 or 6 per IEC 60228) of copper or copper alloy, as well as of aluminium or aluminium alloy. These welded metal-to-metal connections shall employ wires with cross-sectional area of 0,08 mm2 to 160 mm2 and shall not exceed a total cross-sectional area, in case of wire bundle, of 200 mm2. For aluminium or aluminium alloy wires, the minimum required cross-sectional area is 2,5 mm2.
Additionally, information on materials, data from industrial experience and test procedures are included to ensure electrically stable connections under prescribed environmental conditions.
Lastly, this document aims to achieve comparable results when using ultrasonic welding equipment with similar performance and specifications as specified by the termination manufacturer.

  • Standard
    71 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    60 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-10:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for series SMB RF coaxial connectors with snap-on coupling with a characteristic impedance of 50 Ω.
This document prescribes mating face dimensions for high performance connectors – grade 2, dimensional details of standard test connectors − grade 0, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series SMB RF connectors.
This document indicates recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.
The series SMB connectors are used to connect with all kinds of RF cables and microstrips in microwave transmission systems. The operating frequency is up to 4 GHz.

  • Standard
    28 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    20 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63305:2024 specifies methods and procedures for calibration of vector receivers in the frequency range 5 Hz to 10 kHz, which are applicable to vector receivers based on the two different principles. In addition, it describes an absolute method of inertial vector receiver calibration in air using optical interferometry.
Usually, acoustic wave vector receivers are designed and constructed based on one of two principles. One is the sound pressure difference (gradient) principle. When measuring with this sensor, the vector receiver is rigidly fixed on a mount and supported in water. The other is the co-vibrating (inertial) principle. When measuring with this sensor, the vector receiver is suspended on a mount and supported in water in a non-rigid manner, which allows the vector receiver co-vibrate in the same direction as the sound particle in the sound wave field.
Many methods have been used to calibrate vector receivers, such as free-field calibration, calibration in standing wave tube and calibration in a travelling wave tube.

  • Standard
    65 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    55 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-6-101:2024 covers micro fuel cell power systems and fuel cartridges that are wearable or easily carried by hand, providing direct current outputs that do not exceed 60 V DC and power outputs that do not exceed 240 VA. Portable fuel cell power systems that provide output levels that exceed these electrical limits are covered by IEC 62282-5-100. This document covers micro fuel cell power systems and fuel cartridges. This document establishes the requirements for micro fuel cell power systems and fuel cartridges to ensure a reasonable degree of safety for normal use, reasonably foreseeable misuse, and cargo and consumer transportation and storage of such items. . Fuel cartridges refilled by the manufacturer or by trained technicians are covered by this document. The fuel cartridges covered by this document are not intended to be refilled by the consumer.
This first edition, together with the other parts of the IEC 62282-6-1XX series, cancels and replaces IEC 62282-6-100:2010 and IEC 62282-6-100:2010/AMD1:2012. This edition includes the following significant technical changes with respect to IEC 62282‑6‑100:2010 and IEC 62282-6-100:2010/AMD1:2012:
a) A new structure has been set up: IEC 62282-6-101 covers the general safety requirements common to all fuel types whereas IEC 62282-6-102 and subsequent parts of the IEC 62282‑6-1XX series cover particular requirements for specific fuel types based on the requirements given in IEC 62282-6-101.

  • Standard
    58 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies an evaporative ageing procedure, applicable to test specimens of wood and wood-based products which are subsequently subjected to biological tests.
NOTE   The method can also be used for pre-conditioning of untreated wood, modified wood and wood-based panel products, whether they received preservative treatment or not.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    82 pages
    English and French language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    38 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document establishes a system for the designation of supernumerary teeth in humans using two alphanumeric characters.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

RES/EE-EEPS43

  • Standard
    113 pages
    English language
    sale 15% off
  • Standard
    113 pages
    English language
    sale 15% off
  • Standardization document
    113 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61300-2-44:2024 specifies a test to determine the influence of flexing under tensile load of the strain relief of fibre optic interconnecting devices or components. The intention is to simulate the number of flexing cycles which would typically be experienced during service life. This test is applied to both single fibre cable and multiple fibre cable. This fourth edition cancels and replaces the third edition published in 2013. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) replaced active monitoring with transient loss for measurements during test;
b) harmonized recommended severities according to IEC 61753-1.

  • Standard
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63281-2-1:2024 specifies safety requirements and test methods for personal e-Transporters.
This document is applicable to electrically powered personal e-Transporters (PeTs) which are used in private and public areas, where the speed control and/or the steering control is electric/electronic.
The PeT can have provisions for transport of cargo and can be for private or commercial (including sharing service) use.
This document is not applicable for electric vehicles (EVs), such as electrically power assisted cycles (EPACs), e-bikes, mopeds, motorcycles and passenger cars.
This document does not apply to:
- PeTs that are considered as toys;
- PeTs that are intended for competition;
- PeTs that are intended for medical care;
- PeTs that have a rated voltage of more than 100 V DC or 240 V AC;
- PeTs without an on-board driving operator.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    12 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies minimum requirements and a test method for the antimicrobial (microbicidal or microbistatic) activity of wound dressing products. It applies to all wound dressing products that specifically claim antimicrobial activity according to this document.

  • Standard
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    47 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the characteristics and the requirements for sulfamic acids and salts.
Similar to antiscalants as phosphonic acids and its salts (EN 15040) and polycarboxylates and its salts (EN 15039), sulfamic acid and its salts can be used alone or in combination with others drinking water substances as antifoulants (antiscalant effect) for membranes for the treatment of water intended for human consumption.
Sulfamic acid and salts are used in mixtures with sodium hydroxide and sodium hypochlorite or other drinking water chlorine based oxidizing agents as biofilm remover especially for reverse osmosis (RO) and nanofiltration membranes to prevent biofouling by microbiological contamination. The components will not pass the membrane and are rejected to the wastewater with the concentrate. For the other components EN standards are already exist.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 8362-2:2015 specifies the shape, dimensions, material, performance requirements and labelling of closures for injection vials covered by ISO 8362‑1 and ISO 8362‑4.
The dimensional requirements are not applicable to barrier-coated closures.
Closures specified in ISO 8362-2:2015 are intended for single use only.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62282-6-106:2024 covers micro fuel cell power systems, micro fuel cell power units and fuel cartridges using hydrogen produced from UN Class 8 (corrosive) borohydride formulations as fuel. These systems and units use proton exchange membrane (PEM) fuel cell technologies. The designs include fuel processing subsystems to derive hydrogen gas from the corrosive fuel formulation.
This first edition, together with the other parts of the IEC 62282-6-1XX series, cancels and replaces IEC 62282-6-100:2010 and IEC 62282-6-100:2010/AMD1:2012.This edition includes the following significant technical changes with respect to IEC 62282‑6‑100:2010 and IEC 62282-6-100:2010/AMD1:2012:
a) A new structure has been set up: IEC 62282-6-101 covers the general safety requirements common to all fuel types whereas IEC 62282-6-102 and subsequent parts of the IEC 62282-6-1XX series cover particular requirements for individual fuel types.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    13 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    7 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62561-7:2024 is available as IEC 62561-7:2024 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.

IEC 62561-7:2024 specifies the requirements and tests for earthing enhancing compounds producing low resistance of an earth termination system. This third edition cancels and replaces the second edition published in 2018. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Figure A.1 has been replaced with a simpler one that clearly shows the high and low corrosion load limits of the earth enhancing compounds without the need for special knowledge;
b) pH measurement has been introduced.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63403-1:2024 specifies the requirements for specification sheets relating to LED packages designed for horticultural lighting purposes.
LED packages designed for horticultural lighting purposes in this document can be designed for emission of white light or emission of optical radiation at specified wavelengths.
LED packages for horticultural lighting purposes are usually designed into LED modules or luminaires.
This document does not contain compliance criteria, which can be affected by module or luminaire design, and are assumed to be plant species and growth stage dependent.

  • Standard
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

Creating an amendment on European level to mirror the IEC interpretation sheet of IEC 60079-1:2014/ISH1:2020 which is still active at IEC.

  • Amendment
    4 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides guidelines and requirements for designing and conducting an evaluation of single-use adult incontinence absorbing products. It provides guidelines and requirements on creating data collection tools. In particular, it provides a framework for eliciting and recording the views of users and their carers on the acceptability of products. In addition, a product diary is described which can help to quantify some parameters of product use, such as wear times, the mass of urine absorbed by the product and the severity of any leakage from it.
This document does not cover direct comparison between products based on statistical parameters, neither does it provide guidelines on measuring the clinical efficacy of products; that is available in ISO 14155.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    15 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 63403-2:2024 specifies the binning method for LED packages for horticultural lighting.

  • Standard
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 62836:2024 provides an efficient and reliable procedure to test the internal electric field in the insulating materials used for high-voltage applications, by using the pressure wave propagation (PWP) method. It is suitable for a planar and coaxial geometry sample with homogeneous insulating materials of thickness larger or equal to 0,5 mm and an electric field higher than 1 kV/mm, but it is also dependent on the thickness of the sample and the pressure wave generator.
This first edition cancels and replaces IEC TS 62836 published in 2020.
This edition includes the following significant technical changes with respect to IEC TS 62836:
a) addition of Clause 12 for the measurement of space charge distribution in a planar sample;
b) addition of Clause 13 for coaxial geometry samples;
c) addition of Annex D with measurement examples for coaxial geometry samples;
d) addition of a Bibliography;
e) measurement examples for a planar sample have been moved from Clause 12 in IEC TS 62836 to Annex C.

  • Standard
    48 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    43 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies requirements regarding design and test methods for power operated pedestrian doorsets. Examples of how the doorset constructions may be operated include: electro-mechanically, electro-hydraulically, electro-magnetically or pneumatically.
This document covers safety in use of power operated pedestrian doorsets used for normal access as well as in emergency and escape routes and as fire resistance and/or smoke control doorsets.
The type of doorsets covered include power operated pedestrian sliding, swing and revolving doorsets, including balanced doorsets and folding doorsets with a horizontally moving door leaf.
This document deals with all significant hazards, hazardous situations and events relevant to power operated doorsets when they are used as intended and under conditions of misuse which are reasonably foreseeable by the manufacturer.
All lifetime phases of the power operated pedestrian doorsets including transportation, assembly, dismantling, disabling and scrapping are considered by this document.
This document does not apply to:
-   vertically moving doors;
-   doors on lifts;
-   doors on vehicles;
-   power operated doors or gates mainly intended for vehicular traffic or access for goods;
-   doors used in industrial processes;
-   partition walls;
-   doors outside the reach of people (such as crane gantry fences);
-   turnstiles;
-   platform doors;
-   traffic barriers.
This document does not cover special functions of doorsets, such as security in banks, airports, etc. or fire and/or smoke compartmentation, where conformity of the specific function with requirements of the application is the preference.
This document does not deal with any specific requirements on noise emitted from power operated pedestrian doorsets as their noise emission is not considered to be a relevant hazard.
NOTE   Noise emission of power operated pedestrian doorsets is not a significant hazard for the users of these products. It is a comfort aspect.
This document is not applicable to power operated pedestrian doorsets manufactured before the date of its publication.
This document does not cover operation in environments where there is a risk of explosion.

  • Standard
    67 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 60676:2024 This document specifies the basic test procedures, conditions and methods for establishing the main performance parameters and the main operational characteristics of furnaces for direct arc heating, forming arcs between the electrode and metal, such as electric arc furnaces using alternating current (EAF AC) or direct current (EAF DC), and ladle furnaces (LF), with rated power level above 500 kVA .
This fourth edition cancels and replaces the third edition published in 2011. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) The structure has been redrafted according to IEC 60398:2015.
b) The scope has been redrafted.
c) The terms/definitions, normative references and bibliography have been updated and completed.
d) The test methods and content from IEC 60398:2015 have been confirmed, replaced, or complemented with regards to direct arc furnaces (EAF, LF).
e) The annexes from IEC 60398:2015 have been confirmed, replaced, or complemented with regards to direct arc furnaces (EAF, LF).

  • Standard
    41 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

The purpose of this document is to define requirements for marking, identification, leaktightness, electrical and operational safety and mechanical resistance for sanitary tapware with opening and closing controlled electronically.
The conditions of use for the supply system type are specified in Table 2:
[Table 2]
Annex B lists possible consequences of using a product outside its recommended operating range.
[Figure 1]
[Figure 2]
A vented domestic hot water and cold water supply system incorporating gravity hot water, mains cold water and alternative gravity cold water supply to sanitary appliances.

  • Standard
    53 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    51 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements for softboards as defined in EN 316, with a density from 230 kg/m³ to 400 kg/m³.
The values listed in this document relate to product properties but they are not characteristic values to be used in design calculations.
NOTE   Panels which are intended for use exclusively as thermal insulating products are covered by EN 13171.

  • Standard
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day

IEC 61169-70:2024, which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) of HD-BNC series RF coaxial connectors together with the pro forma blank detail specification. HD-BNC series connectors with characteristic impedance of 75 Ω are used with RF cables or micro-strips in microwave, telecommunication, wireless and other fields. The operating frequency limit is up to 18 GHz.
It also prescribes mating face dimensions for general purpose connectors, gauging information and tests selected from IEC 61169-1, applicable to all detail specifications relating to series HD-BNC RF connectors.
This specification indicates the recommended performance characteristics to be considered when writing a detail specification and it covers test schedules and inspection requirements for assessment levels M and H.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    10 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    8 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements and gives recommendations for the design, sizing, installation, identification, commissioning and maintenance of rainwater harvesting systems for the use of rainwater on-site as non-potable water. This European Standard also specifies the minimum requirements for these systems.
Excluded from the scope of this European Standard are:
- the use as drinking water and for food preparation;
- the use for personal hygiene purposes;
- decentralized attenuation;
- infiltration.
NOTE   Conformity with the standard does not exempt from compliance with the obligations arising from local or national regulations.

  • Standard
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    39 pages
    English language
    sale 10% off
    e-Library read for
    1 day